Command Sets

Barcode Printing

Mnemonic FunctionCommandRemarks

DECBAR

Start or Stop Bar

ESC % SP 0

Start barcode

 

Codes

ESC % @

Stop barcode

DECSBCA

Select Bar Code

CSI Ps1 ; Pn2

 

 

Attributes

; . . . ; Ps9 ´ q

 

 

 

 

 

 

Parameters

Description

Values

 

 

 

 

 

Ps1

Bar Code System

0, 2 : Code 39

 

 

 

1 : Interleaved 2 of 5

 

 

 

4 : EAN 8

 

 

 

5 : EAN 13

 

 

 

7 : Codabar a/t

 

 

 

8 : Codabar b/n

 

 

 

9 : Codabar c/*

 

 

 

10 : Codabar d/e

 

 

 

11 : UPC-A

 

 

 

13 : Postnet

 

 

 

14 : Industrial 2 of 5

 

 

 

18 : Matrix 2 of 5

 

Pn2

Width of narrow bars

Supported values : 10 (default) -

 

 

in Decipoints

-15 - 20 - 25 - 30.

 

 

 

Not applicable to UPC, EAN and

 

 

 

Postnet systems.

 

Pn3

Width of quiet zones

Supported value : 180

 

 

in Decipoints

 

 

Pn4

Width of wide bars

Ignored. Set at 2.5 * Pn2.

 

 

in Decipoints

 

 

Pn5

Ignored

 

 

Pn6

Height of bars in

Min = 60

 

 

Decipoints

Max = 2400

 

 

 

Default = 120

 

Pn7

Ignored

 

 

Pn8

Ignored

 

 

Ps9

Human Readable

0, 1 : No HRC

 

 

Characters

2, 3 , 4 : Print HRC

 

 

 

Ignored for Postnet

 

 

 

 

C-14

Page 129
Image 129
Genicom LA36 manual Barcode Printing, Decbar, Decsbca, CSI Ps1 Pn2, Ps9 ´ q