4..3 Projector Management using SNMP

4.. Management with Web browser software

4..3 Projector Management using SNMP

The SNMP (Simple Network Management Protocol) enables to manage the projector information, which is a failure or warning status, from the computer on the network. The SNMP management software will be required on the computer to use this function.

NOTE • It is recommended that SNMP functions be carried out by a network administrator.

SNMP management software must be installed on the computer to monitor the projector via SNMP.

SNMP Settings (71)

Configure the following items via a web browser to use SNMP. Example: If the IP address of the projector is set to 192.168.1.10:

1)Enter “http://192.168.1.10/” into the address bar of the web browser.

2)Enter the Administrator ID and Password and click [Logon].

3)Click [Port Settings] on the main menu.

4)Click [Enable] check box to open the SNMP Port. Set the IP address to send the SNMP trap to when a Failure/Warning occurs.

5)Click [Security Settings] on the main menu.

6)Click [SNMP] and set the community name on the screen that is displayed.

7)Configure the settings for Trap transmission of Failures/Warnings. Click [Alert Settings] on the main menu and select the Failure/Warning item to be configured.

8)Click [Enable] check box to send out the SNMP trap for Failures/Warnings. Clear [Enable] check box when SNMP trap transmission is not required.

9)Click [Apply] button to save the settings.