Use this calibration if an accurate measuring stick is not avail- able.
The panel prompts you to select a printhead to calibrate.
16.Scroll through the printhead numbers to the printhead you want to calibrate, then press the key.
A menu appears listing the pattern versions plus a cancel option:
◆Fine
◆Medium
◆Coarse
◆Cancel Calibration
Begin with the Coarse pattern, and repeat this procedure with the Medium and Fine versions for the best results.
17.Select a pattern and press the key to proceed.
If prompted, remove the supply loop (see page
18.Examine the patterns with a
Fig.
19.Select the pattern with the straightest line of pixels, and enter the pattern number.
Manual Calibrations |