HP 16501A LOGIC To store and time the execution of a subroutine Example, As shown in the display

Models: 16500C 16501A LOGIC

1 130
Download 130 pages 6.88 Kb
Page 14
Image 14

Triggering

To store and time the execution of a subroutine

Example

Suppose you want to trigger on entry to a routine called MY_SUB. You can

 

define the address of MY_SUB in the Format menu, allowing you to reference

 

the symbol name when setting up the trace specification. Assume that

 

MY_SUB extends for 0A hex locations. You can set up the trigger sequencer

 

as shown in the display.

 

 

 

 

 

 

Trigger Setup for Storing Execution of a Subroutine

For processors that do prefetching of instructions or have pipelined architectures, you may want to add part or all of the depth of the pipeline to the start address for In_Range1 to ensure that the analyzer does not trigger on a prefetched but unexecuted state.

1–4

Page 14
Image 14
HP 16501A LOGIC, 16500C manual To store and time the execution of a subroutine Example, As shown in the display