Model L10 Long-Wave Hub

Note

Stated distances assume 9-micron single-mode cable for the long-wave port and

 

50-micron multimode cable for the short-wave ports.

For ports 1 through 9, the long-wave hub supports distances of 500 meters between the port and a connected FC-AL device. For the long-wave port, the long-wave hub supports distances up to 3 kilometers between two long-wave hubs. Under certain conditions, cascaded long-wave hubs are supported at distances up to 10 kilometers. The 10-km capability is supported only for long-wave hubs connected to HP-UX servers.

To verify 10-km capability for the long-wave hub over an existing cable plant:

The received average optical power of the long-wave port on both long-wave hubs must be higher (more positive) than -17 dBm in order for the long-wave hubs to support cascade distances of up to 10 km. Use an optical power meter that measures average optical power at a wavelength of 1300 nm in dBm units (for example, the Fotec Model 712A Power Meter with Model A262 SC connector adapter).

To verify the long-wave port’s received average optical power, do the following:

1.Power on both long-wave hubs and connect the long-wave ports with the 10-km single- mode cable.

2.Turn the optical power meter on. The meter performs a self-test.

3.If necessary, set the meter’s wavelength to 1300 nm and measuring units to dBm.

4.Disconnect the Fibre Channel cable from the long-wave port of one of the two hubs.

5.Determine which connector of the Fibre Channel cable is the transmitter. Connect one plug of the Fibre Channel cable into the SC receptacle of the meter. If the meter does not indicate a signal, connect the other plug of the Fibre Channel cable.

6.Verify that the reading on the meter is higher (more positive) than -17 dBm and lower than -3 dBm.

7.Reconnect the Fibre Channel cable to the long-wave port.

8.Repeat steps 4 through 7 with the long-wave port of the second long-wave hub.

Reference

Operating Requirements

105