Cascaded Short-Wave Hub Topology

The example in Figure 5 shows two model S10 hubs connected in a cascade topology. Cascaded short-wave hubs use one port on each hub for the hub-to-hub connection. Such a configuration increases the potential distance between nodes in the loop an additional 500 meters. The maximum distance between the server and FC-AL devices with cascaded short-wave hubs is 1500 meters (1.5 km).

Figure 5 Example Topology: Cascaded Short-Wave Hubs

500 m

HP-UX Server

or

HP NetServer

NOTE: Connecting HP-UX servers and HP NetServers to the same hub is NOT

a supported configuration.

Maximum distance between

server and FC-AL device = 1500 m

model S10 hub

model S10 hub

...................................

...............................

.....

 

500 m

500 m

 

FC-AL Devices

FC-AL Devices

Cascaded hubs must have the same firmware versions to operate properly. If you are using Fibre Channel Manager to manage cascaded hubs, configure the hub that has the LAN (ethernet) connection as a parent hub and the remaining hub as a child hub (see Configuring Cascaded Hubs on page 60).

18Supported Topologies