4.Verify that the 10Base-T port is operating properly. Insert an ethernet cable that is connected to the LAN into the 10Base-T port, and verify that the 10Base-T status LED turns on. (The status LED may begin flashing.)

5.Set the hub IP address and configure the hub as described in chapter 3, RS-232 Interface Functions.

6.Verify the connection between the HP-UX server and the hub. At the management server where Fibre Channel Manager is or will be installed, execute the following command:

/etc/ping <hub IP address>

Example: /etc/ping 15.43.214.13

Fibre Channel Manager requires HP-UX 10.20 or 11.0 on the management server.

If you are unable to ping the hub, refer to If the Management Server Cannot Ping the Hub on page 78.

7.Unplug the hub.

26Procedure 3: Verify Hub Operation