Chapter 6 | Replacing Parts |
CAUTION Do not touch the components as you push the VRM down into the slot.
3.Gently insert the VRM into the socket.
4.
Replacing the Power Supply Fans
The power supply fans are mounted on removable brackets just forward of the power supply cage(s). Each bracket contains two fans. The fans are not individually replaceable; you must replace them both, and the bracket, as a unit. These units may be
CAUTION Do not run this NetServer for more than 60 minutes without all covers in place. Any component being replaced must be removed and a replacement installed within this
Follow these instructions to remove and replace the power supply fans:
1.Back up the hard disk drive(s) and save the configuration.
2.If necessary, shutdown the network operating system.
3.Turn off the HP NetServer and display.
4.Disconnect all telephone cables and power cords.
5.Remove cover.
6.Lift the ejection handle to release the fan bracket from the chassis. Remove the bracket from the chassis.
90