Manuals
/
HP
/
Computer Equipment
/
Network Card
HP
MicroLogix 1761-NET-ENI
manual
Models:
MicroLogix 1761-NET-ENI
1
50
102
102
Download
102 pages
23.71 Kb
47
48
49
50
51
52
53
54
Specifications
Install
System Diagram
Default Settings
LED Indicators
External Power Supply Wiring
Dimension
ENI Configuration Node 248 to
Reset
Pccc Description No access
Page 50
Image 50
5-6
Peer-to-Peer
Messaging
Publication
1761-UM006A-EN-P
- February 2001
Page 49
Page 51
Page 50
Image 50
Page 49
Page 51
Contents
MicroLogix Ethernet Interface ENI
Cat. No -NET-ENI
Allen-Bradley is a trademark of Rockwell Automation
Table of Contents
Chapter
Preface
Who Should Use this Manual
Related Documentation
For Read this Document
Your Questions or Comments on this Manual
Local Product Support
Technical Product Assistance
Preface P-4 Publication 1761-UM006A-EN-P January
Product Overview
Ethernet Connection Non-Ethernet Devices
Product Drawing
Hardware Features
LED Indicators
Description Function Color
DF1 Settings Default Other Options
Default Settings
RS-232 Settings Default Other Options
Messaging
Operating Modes
Device Compatibility
Mail
Basic Ethernet Topology
Using a Web Browser with the ENI
Ethernet Networks
6Product Overview Publication 1761-UM006A-EN-P February
EMC Directive
Low Voltage Directive
Safety Considerations
Mounting
DIN Rail Mounting
Panel Mounting
Removal
External Power Supply Wiring
ENI Port Identification
Pin Pin Name
Ethernet 8-Pin 10Base-T Connector Port
Ethernet Connections
Ethernet Cables
Maintain ENI Connections
RS-232 Cables
RS-232 Connector
RS-232 Connector Pin Assignments
ENI Connected to Catalog Number Use Cable
Outgoing messages
Operation Overview
Number of Connections Dedicated to
Incoming messages
RSLinx on Ethernet PC Connected to Ethernet
ENI Functional Overview
Operation
4Operation
RSLogix
6Operation
ENI Configuration Node 248 to
ENI Configuration Utility
COM Port Settings
RS-232 Baud Rate and TCP/IP Parameters
Mail Settings
Save to ENI RAM or ENI ROM
Reset
Message Routing
Controller Messaging
Configuring ENI Data Parameters
Target Device Parameters
Configuring ENI String Parameters
Configuring the ENI E-Mail From String
Always set this to
Node Function Data Type Number Options Default Elements
Node 249 From String
Node 248 Save/Reset Function
Save/Reset
Value
Node 250 TCP/IP Configuration
TCP/IP Configuration Parameters Function Data Type Length
Subnet Mask is set to
Subnet Mask Auto-Detect Operation
Subnet Mask is in auto-detect
Security Mask Behavior Example Condition
Node 253 Baud Rate
Node 252 Bootp Configuration
Node 251 E-Mail Server
ENI Baud Rate Options Configuration Value Integer
Node 254 Ethernet Hardware Address
Peer-to-Peer Messaging
Node Node100
Configuration Node TCP/IP address
Message Routing ENI receives read or
Node Node101
102 Route 2 Address
100 Route 0 Address
101 Route 1 Address
103 Route 3 Address
148
DF1 Message Routing
Function ENI Node
Use any command supported by your controller
Data Table Address Use any valid file Size in Elements
Page
Mail Messages Node 50 to
Overview
Configuring E-Mail
Smtp E-Mail Address
Destination Addresses
Message Text
Node
Mail Mail Address Description Message Configuration
Message Fields to, from, subject
Sending an E-Mail Message
Mail messages
System Diagram
Example Network
Purpose Scope
RSLOGIX500
131.200.50.96 Computer’s Ethernet card
Example Network IP Addresses Device
131.200.50.95
Configuring 1761-NET-ENI #1
Throttling Message Instructions
ENI #1 Configuration ENI IP Addr Screen
Configuring 1761-NET-ENI #2
Message Routing Nodes Function
ENI #2 Configuration RSLogix 5000 Ladder Program
Message Message Function
ENI #2 Configuration Rung Descriptions Function
ENI #2 Configuration Message Instructions Parameters
Publication 1761-UM006A-EN-P February
ENI #2 Configuration Message ConfigurationTab
10 L20 Controller’s Tags
11 File Mapping in RSLogix
Configure Rslinx
1769-L20
13 Modify DF1 Parameters Using RSLInx
14 SLC 5/05 Controller Ladder Program
15 SLC 5/05 Rung 0 MSG General Tab
17 SLC 5/05 Rung 1 MSG General Tab
19 ControlLogix 5550 Controller Ladder Program
20 ControlLogix 5550 Rung 0 Message Configuration Tab
22 ControlLogix 5550 Rung 1 Message Configuration Tab
Configuring an Ethernet Driver in Rslinx
25 Configure Ethernet Driver Using RSLinx
Flashes for 4 seconds
Power-Up Sequence
On solid for 2 seconds
Description Color State Indicates
Error Code Description of Error Condition
Message Instruction Error Codes
Error Codes Generated by the ENI
Connection not completed before user-specified timeout
Pccc Description Remote station problem due to download
Pccc Description Cannot execute command due to active IPBs
Reply not received before user-specified timeout
Pccc Description Data conversion error
Pccc Description Command cannot be executed
Pccc Description No access
Pccc Description Overflow histogram overflow
6Troubleshooting Publication 1761-UM006A-EN-P February
MicroLogix Web Site
Physical Specifications
Description ENI Specification
Product Dimensions
Dimensions
Mounting Dimensions
Gateway Optional1
TCP/IP Parameters Function Format
On the subnet mask
Zero
Using Bootp
Install the Bootp Server
Edit the Bootp Configuration File
Device Name IP Address Hardware Address
Ethernet TCP/IP
Parameters if necessary Windows
From See This platform Executable
DOS-based
Windows Program Manager
Parameter Description
Running the DOS-Based Utility
Running the Windows-Based Utility
Glossary
Node
Pccc Programmable Controller Communications Commands RS-232
UTP Unshielded Twisted Pair
Allocation of Ethernet connections 3-1Ethernet switch
Index
MTA
TCP
Index Publication 1761-UM006A-EN-P February
Page
Publication 1761-UM006A-EN-P February
Top
Page
Image
Contents