HP MicroLogix 1761-NET-ENI manual Device Name IP Address Hardware Address, Ethernet TCP/IP

Models: MicroLogix 1761-NET-ENI

1 102
Download 102 pages 23.71 Kb
Page 90
Image 90

B-4BOOTP Configuration Method (default)

HP 9000

HP UNIX Computer

2.Make one copy of the configuration template for each ENI in your system.

3.Edit each copy of the template as follows:

a.Replace “sigma1” with the name of the ENI. Use only letters and numbers; do not use underscores.

b.Replace “12.34.56.1” with the IP address to be assigned to the ENI.

c.Replace “ha=0000BC1D1234” with the ENI’s hardware address. Use only hexadecimal digits (0-9, A-F); do not use the hyphens that separate the numbers.

4.Save, close, and make a backup copy of this file.

Example BOOTPTAB File

In this example there are three SLC 5/05 processors and an HP 9000 programming terminal. The names and hardware addresses are device specific:

Device

Name

IP Address

Hardware Address

 

 

 

 

SLC 5/05

sigma1

12.34.56.100

00-BC-1D-12-34

 

 

 

 

SLC 5/05

sigma2

12.34.56.200

00-BC-1D-56-78

 

 

 

 

SLC 5/05

sigma3

12.34.56.300

00-BC-1D-90-12

 

 

 

 

802.3 Ethernet (TCP/IP)

BOOTP Server

sigma1

sigma2

sigma3

SLC 5/05 Processor

SLC 5/05 Processor

SLC 5/05 Processor

Publication 1761-UM006A-EN-P - February 2001