6.Add one connection to the FlatSAN B network. Enter the information shown in the following table, and then click Add to add the connection and close the dialog box.

Attribute

Value

Device type

Fibre Channel

 

 

Network

FlatSAN B

 

 

Requested bandwidth

2.5 (the default value)

 

 

FlexNIC

Auto (the default value)

 

 

Boot

Not bootable

 

 

The following illustration shows the Connections panel for the server profile after you add the connections.

7.Scroll down to display the lower half of the Create server profile dialog box.

8.Configure the boot order for this server profile. Ensure that Manage boot order is selected. Drag and drop the items so that they are in this order:

1.CD

2.HardDisk

3.Floppy

4.USB

5.PXE

Notice that the number next to each item is adjusted automatically when you use the drag-and-drop method to change the order.

9.Edit the BIOS settings. For example: a. Select Manage BIOS.

262 Step by step: Configuring an example data center using HP OneView