27.5 Troubleshooting enclosures and enclosures groups

27.5.1 Add or remove enclosure is unsuccessful

Symptom

Possible cause and recommendation

 

 

 

 

 

 

 

Unable to add an

If the enclosure add fails, a notification panel provides the reason the add action failed and

enclosure

provides a solution to the problem. Often, the resolution is to click the add link that is embedded

 

in the message; the add action rediscovers all components and updates its knowledge of the

 

enclosure.

 

 

 

Enclosure is already being managed by some other management software

 

and is claimed by that software

 

1.

If a first-time enclosure add fails, verify that the enclosures prerequisites listed in add an

 

 

enclosure to manage its contents are met. Verify that the data you entered on the screen is

 

 

corrects, and try the action again.

 

 

 

2.

Follow the guidance in the notification panel for the corrective action you need to take to

 

 

successfully add the enclosure.

 

 

 

 

Failures can occur during the add action if all information about an enclosure, its server

 

 

blades, or interconnect modules cannot be acquired. When this happens, an explanation

 

 

of the problem and the component that caused the problem (the enclosure, a server blade,

 

 

an interconnect) is provided in a notification panel.

 

3.

To re-add an enclosure, click the add link in the notification message panel (if there is one),

 

 

or start the add action again from the Add Enclosure screen, supplying the address and

 

 

credentials for the enclosure's Onboard Administrator.

 

To forcibly add the enclosure to the appliance, see the UI help for enclosures.

 

 

 

 

 

Unable to forcibly add

You forcibly added an enclosure but received an error message. This happens only in some

an enclosure

cases where there is a VCMode set and virtual connect is managing the enclosure.

 

1.

Manual clean-up of the configuration is needed, investigate the following items:

 

 

The management URL might still point to the appliance. If so, it needs to be reset to point

 

 

 

at the first interconnect in the enclosure. To fix this, use the following ssh commands to

 

 

 

go into the Onboard Administrator (using administrator credentials) and change the

 

 

 

management URL to point to the first active VC interconnect's IP address:

 

 

 

 

 

 

 

 

 

clear vcmode

Disassociates the enclosures from the appliance.

 

 

 

 

 

 

 

 

 

restart interconnect

(where N is the bay number of a VC interconnect)

 

 

 

 

N

Preforming this step for every VC interconnect in the

 

 

 

 

 

enclosure causes the interconnect to revert to a default

 

 

 

 

 

configuration.

 

 

 

 

 

 

 

 

 

 

restart oa N

(where N is the bay number of the active Onboard

 

 

 

 

Administrator) This causes the OA to obtain the

 

 

 

 

management URL from the first VC interconnect.

 

 

 

 

 

 

 

2.

After manual configuration, Re-add an enclosure or refresh the enclosure.

 

 

 

 

 

An existing enclosure

You replaced the enclosure midplane but did not follow the recommended procedure in the

is detected as being

hardware documentation.

 

 

new after a midplane

Recommendation: Re-add an enclosure

is replaced

 

 

 

 

 

208 Troubleshooting