Symptom Possible cause and recommendation

A profile operation

The server hardware or its iLO are powered-off or reset

timeout when

In most cases, retrying the operation resolves the problem

applying BIOS

settings

The appliance cannot collect progress information from the iLO

 

In most cases, retrying the operation resolves the problem

Auto-assignment for

Invalid configuration

FlexNIC fails while

Auto-assignment for FlexNIC connections does not validate the following:

deploying

connections

Bandwidth oversubscription on the physical port

 

 

Maximum networks (VLANs) on the physical port

 

Duplicate networks (VLANs) on the physical port

 

Manual assignment is required

27.12.2 What to do when you cannot apply the server profile

Symptom

Cannot apply the server profile

Cannot verify the status of the server hardware

Possible cause and recommendation

If you cannot apply the server profile because the PXE boot does not boot within the expected amount of time, reset the iLO.

Verify the operational status of the server hardware

1.Click Cancel to exit from the Create Server Profile screen.

2.From the main menu, navigate to the Server Hardware screen.

3.Find, and then select the server hardware.

27.12 Troubleshooting server profiles 217

Page 217
Image 217
HP OneView manual What to do when you cannot apply the server profile, Server hardware or its iLO are powered-off or reset