Symptom

Possible cause and recommendation

A profile operation

The server hardware or its iLO are powered-off or reset

timeout when

In most cases, retrying the operation resolves the problem

applying BIOS

settings

The appliance cannot collect progress information from the iLO

 

In most cases, retrying the operation resolves the problem

 

 

Auto-assignment for

Invalid configuration

FlexNIC fails while

Auto-assignment for FlexNIC connections does not validate the following:

deploying

connections

Bandwidth oversubscription on the physical port

 

 

Maximum networks (VLANs) on the physical port

 

Duplicate networks (VLANs) on the physical port

 

Manual assignment is required

 

 

27.12.2 What to do when you cannot apply the server profile

Symptom

Possible cause and recommendation

 

 

Cannot apply the

If you cannot apply the server profile because the PXE boot does not boot within the expected

server profile

amount of time, reset the iLO.

 

 

Cannot verify the

Verify the operational status of the server hardware

status of the server

1.

Click Cancel to exit from the Create Server Profile screen.

hardware

2.

From the main menu, navigate to the Server Hardware screen.

 

 

3.

Find, and then select the server hardware.

 

 

 

27.12 Troubleshooting server profiles 217