Interfaces

Minimum Number of Kilobytes for Spooling

Sets the minimum number of kilobytes of system memory allocated to the parallel interface.

Menu

Administration/Communications/Parallel/Min K Spool

 

 

Choices

00000-99999

 

 

Default

00015

 

 

Notes

This value must be less than K Mem For Spool.

 

A 00000 value does not turn off the spooling buffer for the

 

parallel interface. If the value is set to 00000, the printer

 

calculates the Min K Spool automatically at initialization.

 

The printer must be restarted for changes to the Min K Spool

 

menu to take effect. You can either let the printer restart

 

automatically after you save the change and exit from the

 

configuration menu, or you can wait for the change to take

 

effect the next time you manually turn on the printer.

 

 

Mode

The parallel interface supports Centronics parallel communication as well as IEEE 1284 bidirectional (two-way) parallel communication, which provides five modes of operation: byte, compatibility, ECP (enhanced compatibility port), EPP (enhanced parallel port), and nibble. See chapter 5, “Additional Technical Information,” for a discussion of the different modes.

Menu Administration/Communications/Parallel/Mode

Choices Interactive—Establish bidirectional (IEEE 1284) parallel communication between the host and the printer.

Noninteractive—Establish Centronics parallel communication from the host to the printer.

Disabled—Turn off parallel communication with the host. The printer stops accepting print jobs over the parallel interface.

Default Noninteractive

Printer Configuration