DETector:BANDwidth?

[SENSe:]DETector:BANDwidth? returns which ac filter has been selected. The value returned is 3, 20 or 200. The value is sent to the output buffer.

Example Query the Detector Bandwidth

DET:BAND 200

Select 200Hz bandwidth (fast filter).

DET:BAND?

Query multimeter to return the detector

 

bandwidth setting.

FREQuency:APERture

[SENSe:]FREQuency:APERture <time> selects the aperture time (or gate time) for frequency measurements.

Parameter Name

Parameter Type

Range of Values

Default Units

 

 

 

 

<time>

numeric

0.010.11MINMAX

seconds

 

 

 

 

 

 

 

 

Comments Specify 0.01 (10ms) for 4½-digits, 0.1 (default, 100ms) for 5½-digits or 1 second for 6½-digits.

MIN = 0.01, MAX = 1.

*RST Condition: 0.1 seconds

Example Set a Frequency Aperture Time of 1 Second

FREQ:APER 1

Sets aperture time to 1 second.

FREQuency:APERture?

[SENSe:]FREQuency:APERture? [MINMAX] queries the aperture time for frequency measurements. The MIN parameter returns the minimum aperture value (0.01); the MAX parameter returns the maximum aperture value (1).

128 Multimeter Command Reference

Chapter 3

Page 128
Image 128
HP WaterSkis E1312A, WaterSkis E1412A DETectorBANDwidth?, FREQuencyAPERture?, Example Query the Detector Bandwidth