CALCulate

There are five math operations available (AVERage, DB, DBM, LIMit, and NULL), only one can be enabled at a time. Each performs a mathematical operation on every reading or stores data on a series of readings. The selected math operation remains in effect until you disable it, change functions, turn off the power, or perform a remote interface reset. The math operations use one or more internal registers. You can preset the values in some of the registers, while others hold the results of the math operation.

The following table shows the math/measurement function combinations allowed. Each “ X” indicates an allowable combination. If you choose a math operation that is not allowed with the present measurement function, math is turned off. If you select a valid math operation and then change to one that is invalid, a “Settings conflict” error is generated over the remote interface. For null and dB measurements, you must turn on the math operation before writing to their math registers.

Valid Math/Measurement Function Combinations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measurements

 

 

 

 

 

 

 

DCV

 

ACV

 

DCI

 

ACI

 

Ω2W

 

Ω4W

 

Freq

 

Per

 

Ratio

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVERage

X

 

X

 

X

 

X

 

X

 

X

 

X

 

X

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DB

X

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DBM

X

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIMit

X

 

X

 

X

 

X

 

X

 

X

 

X

 

X

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NULL

X

 

X

 

X

 

X

 

X

 

X

 

X

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Subsystem Syntax

CALCulate

 

:AVERage:AVERage?

 

:AVERage:COUNt?

 

:AVERage:MAXimum?

 

:AVERage:MINimum?

 

:DB:REFerence <value> MINMAX

 

:DB:REFerence? [MINMAX]

 

:DBM:REFerence <value> MINMAX

 

:DBM:REFerence? [MINMAX]

 

:FUNCtion AVERageDBDBM LIMitNULL

 

:FUNCtion?

 

:LIMit:LOWer <value> MINMAX

 

:LIMit:LOWer? [MINMAX]

 

:LIMit:UPPer <value> MINMAX

 

:LIMit:UPPer? [MINMAX]

 

:NULL:OFFSet <value> MINMAX

 

:NULL:OFFSet? [MINMAX]

 

:STATe OFFON

 

:STATe?

Chapter 3

Multimeter Command Reference 73

Page 73
Image 73
HP WaterSkis E1412A, WaterSkis E1312A manual CALCulate, Subsystem Syntax, Valid Math/Measurement Function Combinations