Solving Known Problems |
Table
Intermittent failure of a configured LEC to connect to the LECS or LES
Symptom:
■Insufficient resource error message.
■LECs fail but seem to automatically recover.
■The MAX VPI Bits and MAX VCI Bits settings are incompatible between ATM devices. For example, if auto- configuration is not enabled, and the MAX VPI/VCI Bits have been set up incorrectly.
■Each ATM device supports a separate and sometimes different
Example:
If Switch A supports VPI/VCI values 7:511 and Switch B only supports values up to 7:255, when Signalling tries to set up a connection using the VPI/VCI value 7:256, Switch B rejects the connection.
Identify the connection that is causing the problem. The following steps should be carried out in order:
1Check that the MAX VPI/VCI Bits are compatible on the
2Check that the MAX VPI/VCI Bit settings are compatible on all devices between the
3Check that the MAX VPI/VCI Bit settings are compatible on all ATM devices between the LEC and the LES.
When you have identified the connection, manually reconfigure the VPI/VCI values to make them compatible.
If you have problems that are not addressed by troubleshooting information in this guide, contact Technical Support, or your service person. For Technical Support information refer to Appendix E.