Chapter
Display Messages and LED Indications
Error/Event | IRI | Error No. | Comment |
|
|
|
|
Operational | On | 0 | No error |
|
|
|
|
Out of paper | Blink | 1005 |
|
|
|
|
|
Next label not found | Blink | 1031 |
|
|
|
|
|
Label not taken | Blink |
|
|
|
|
|
|
Out of transfer ribbon | Blink | 1027 |
|
|
|
|
|
Transfer ribbon is installed | Blink | 1058 |
|
Head lifted | Blink | 1022 |
|
|
|
|
|
Cutter does not respond | Blink | 1059 |
|
|
|
|
|
Cutter error1 | Blink | 1701 |
|
|
|
|
|
Cutter error2 | Blink | 1702 |
|
|
|
|
|
Cutter error3 | Blink | 1703 |
|
|
|
|
|
Cutter open | Blink | 1704 |
|
|
|
|
|
Lss too high | Blink | 1007 |
|
|
|
|
|
Lss too low | Blink | 1008 |
|
|
|
|
|
Testfeed not done | Blink | 1606 |
|
|
|
|
|
Pause Mode entered | Blink |
|
|
|
|
|
|
Setup Mode entered | Blink |
| Including interactive setup from |
|
|
| Fingerprint/Direct Protocol |
|
|
|
|
IP link error | Blink |
| See note 1, 2, and 3 |
|
|
|
|
IP configuration error | Blink |
| See note 1, 3, and 4 |
|
|
|
|
Generic DP error | Blink |
| See note 5 |
|
|
|
|
Press any key to continue | Blink |
| See note 6 |
|
|
|
|
Application load error | Blink |
| See note 7 |
|
|
|
|
IRI blink by application | Blink |
| Set by Fingerprint instruction |
|
|
| SYSHEALTH |
|
|
|
|
IRI off by application | Off |
| Set by Fingerprint instruction |
|
|
| SYSHEALTH |
|
|
|
|
Application break | Off |
| See note 8 |
|
|
|
|
Printhead not found | Off |
|
|
|
|
|
|
Rebooted | Off |
|
|
|
|
|
|
Inizializing | Off |
| Set at startup until operational |
|
|
|
|
Intermec EasyCoder PF4i Compact | 93 |