Appendix
RS-232 Interface
Protocol
Default setup: |
|
Baud rate: | 9600 |
Char. length | 8 bits |
Parity: | None |
Stop bits: | 1 |
RTS/CTS | Disabled |
ENQ/ACK: | Disabled |
XON/XOFF: | Disabled (both ways) |
New Line: | CR/LF |
To change the
Signals on printer’s serial port "uart1:"
| Signal | Meaning |
|
|
|
1 |
| External +5V DC* |
|
|
|
2 | TXD | Transmit data |
|
|
|
3 | RXD | Recieve data |
|
|
|
4 | DSR | Data set ready |
|
|
|
5 | GND | Ground |
|
|
|
6 | DTR | Data terminal ready |
|
|
|
7 | CTS | Clear to send |
|
|
|
8 | RTS | Request to send |
|
|
|
9 | – | Not used |
|
|
|
("uart1:")
*/. The external +5V is limited to 500 mA and is automatically switched off at overload.
Interface Cable
Computer end: Depends on computer model
Printer end: |
132 Intermec EasyCoder PF4i Compact