Chapter 8—Intermec Shell Startup Program

Line Analyzer

The Line Analyzer (LINE_AXP.PRG) is a program written in the Intermec Fingerprint programming language and is intended to help solving possible communication problems. As the name implies, the Line Analyzer captures all incoming characters on a specified communication channel and prints them on one or more labels.

Printable characters are printed in black-on-white, whereas control characters and space characters (ASCII 000–032 dec) are printed in white-on-black.

While the printer is receiving data, the “Ready” control lamp blinks. There is a 0.5 second timeout. That is, if no more characters have been received after 0.5 second, the program considers the transmission termi- nated and prints out a label.

As long as a continuous string of characters is being received, the pro- gram wraps the lines until the label is full and then starts to print another label. At the bottom of each label, the following information is printed:

Page number

Number of characters printed on the label

Total number of characters received so far

The Line Analyzer is displayed as the option “LINE_AXP.PRG" under the “SEL. APPLICATION” menu. After the Line Analyzer has been selected and the printer has started up again, the printer feeds out two labels and the following menu is displayed:

Line Analyzer

Sel.port(1-6) 1

Enter the desired communication port using the numeric keys on the printer’s keyboard:

1 = "uart1:"

2 = "uart2:"

3 = "uart3:"

4 = "centronics:"

5 = "net1:"

6 = "usb1:"