Chapter 6—Setting Up the Printer

Setup Parameters

Serial Communication

The serial communication parameters control the communication between the printer and the connected computer or other devices on the standard serial port "uart1:" and the optional serial ports "uart2:" and "uart3:". The optional ports require an optional interface board. The printer’s firmware detects if an interface board is installed in the printer and presents additional sets of communication setup menus depending on type of communication (refer to diagrams 3-5 in Chapter 7, “Setup Mode”).

Note: The serial communication parameters have no effect on parallel or EasyLAN communications, or on the IN and OUT ports on the optional Industrial Interface Board.

For the serial communication channel "uart1:", the following parameters can be set. Make sure they match the setup of the connected device or vice versa. If the setup of the printer and the setup of the host do not match, the response from the printer to host will be garbled.

Baud Rate

The baud rate is the transmission speed in bits per second. There are 10 options:

300

600

1200

2400

4800

9600

(default)

19200

 

38400

 

57600

 

• 115200

Intermec EasyCoder PF4i Compact Industrial—User’s Guide (Fingerprint)