Chapter
Thermal Transfer Printing
• | Ribbon Constant | (range 50 to 115) |
• | Ribbon Factor | (range 10 to 50) |
• | Label Offset | (range |
• | Ribbon Sensor | (autoadjustment) |
• | Low Diameter | (range 25 to 80 mm) |
When adjusting the image darkness for
General Paper Type Settings Guide (Thermal Transfer)
Type | Ribbon | Ribbon | Max Print Speed | |
| Constant | Factor | 8 dots/mm | 11.81 dots/mm |
Wax (Europe) | 80 | 25 | 150 | 125 |
Wax (U.S.A.) | 65 | 25 | 150 | 125 |
Wax/Resin (Europe) | 90 | 25 | ||
Wax/Resin (U.S.A.) | 75 | 25 | ||
Resin (Europe) | 100 | 30 | 200 | 150 |
Resin (U.S.A.) | 90 | 30 | 200 | 150 |
The Ribbon Sensor parameter is
The resulting setting is displayed in the menu.
The Low Diameter parameter specifies the diameter of the ribbon supply roll, where SYSVAR(26) switches from 0 to 1. SYSVAR(26) = 0 means that there is still a sufficient supply of ribbon, whereas SYSVAR(26)
=1 means that it is time to consider replacing the ribbon supply. The diameter is expressed in millimetres (1 mm = 0.04 in.) and an accuracy of ±3 mm can be expected. Note that this setting has little effect unless SYSVAR(26) is read by a Fingerprint program. However, Error 1083 “Ribbon Low” is reported at every tenth printing operation. By default, the low diameter is 0, that is, the ribbon low function is disabled.
58 Intermec EasyCoder PF4i Compact