MENU SCREEN | – Contents of the menus – (continued) | ||||
|
|
|
|
| |
SYSTEM menu (continued) |
|
| |||
|
|
|
|
|
|
Items | Setting |
|
|
| Contents |
|
|
|
| ||
INDEX WRITE | OFF |
| Use this setting to enable/disable index signal recording: | ||
| ON |
| OFF | : No recording of index signal. | |
|
|
| ON | : Use this setting to record index signals. An index signal is | |
|
|
|
| automatically registered at the position where recording | |
|
|
|
| starts. |
|
|
|
|
| ||
REPEAT MODE | OFF |
| Use this setting to enable/disable repeat playback: | ||
| INDEX |
| OFF |
| : No repeat playback. |
| VIDEO OUT |
| INDEX | : Repeat playback between the positions where in- | |
| TAPE END |
|
|
| dex signals are recorded. |
|
|
| VIDEO OUT | : Repeat playback from the beginning of the tape to | |
|
|
|
|
| the position where recording of video signals ends. |
|
|
| TAPE END | : Repeat playback from the beginning to the end of | |
|
|
|
|
| the tape. |
|
|
|
| ||
NEXT PAGE |
|
| Display the SYSTEM (2/2) menu. | ||
|
|
|
| ||
PAGE BACK |
|
| Return to the top MENU. | ||
|
|
|
|
|
|
SYSTEM (2/2) menu
Items | Setting |
|
|
| Contents | |
|
|
|
|
|
| |
DC IN MODE | OPE OFF | Select the action to perform when power is supplied via the DC IN | ||||
| OPE ON | terminal: |
|
| ||
| PLAY | OPE OFF | : Sets the unit to OPERATE OFF. | |||
|
| OPE ON | : Sets the unit to OPERATE ON. | |||
|
| PLAY | : If a tape has been inserted, the VTR will go into the | |||
|
|
|
|
| PLAY mode. (AUTO PLAY) | |
|
|
|
|
|
| |
OPERATION | OFF | Turn ON/OFF the OPERATION LOCK: | ||||
LOCK | ON | OFF : Turns off the OPERATION LOCK and enables the buttons | ||||
|
|
|
| on the main unit. | ||
|
| ON : VTR goes into the OPERATE LOCK mode.The buttons and | ||||
|
|
|
| the slide switch on the main unit are inhibited. However, | ||
|
|
|
| OPERATE ON and menu operations are still possible. | ||
|
|
|
| Memo |
|
|
|
|
|
| this setting is OFF, disabling the buttons on the main | ||
|
| Even when | ||||
|
| unit while it is controlled via a remote controller connected to the 9 | ||||
|
| PIN REMOTE or SERIAL REMOTE terminal is possible, by setting | ||||
|
| the LOCAL FUNCTION item of the REMOTE menu. | ||||
|
|
|
|
|
| |
PAGE BACK |
| Return to the SYSTEM (1/2). | ||||
|
|
|
|
|
|
|