Diagnostics - Debug tab The Debug tab allows you to store the communications between the scanner and a scanning application, as well as the images, to a file that can be reviewed later by Kodak support personnel.

Logging — saves the communications between the scanner and a scanning application. The options are: Off (the default), On or Custom. It is suggested that you do not use the Custom setting, unless directed to do so by Kodak support personnel.

NOTES:

Flag and Filter are only available for Custom; only make changes as directed by Kodak support personnel.

For changes to take effect, you must restart your application.

Images

Received From Scanner: normally, it is not necessary to save the images received at the PC from the scanner. It is suggested that you only turn this on when instructed by Kodak support personnel.

-Save: normally, it is not necessary to save the images received at the PC from the scanner. It is suggested that you only turn this on when instructed by Kodak support personnel.

-File prefix: the scanner will apply the entered text to the beginning of each file created. This can be used to more easily find and sort the saved images.

-Held in memory: if scanning a large job and you only need to save the last few images, then turn this on by selecting the number of images you want to save.

NOTE: Turning this on will use more PC memory.

A-61550 May 2007

95

Page 100
Image 100
Kodak I1400 manual Images