Multi-feed Detection options
•Length Detection enable or disable (the default) this option. If enabled, select the maximum length of the document that can be scanned without a
•Auto Set: automatically sets the maximum length value
Ultrasonic Detection — check this option to set
•Sensitivity — controls how aggressively the scanner will work to determine if more than one document is fed into the transport. Multi- feeds are triggered by detecting air gaps between documents. This allows
-Low: the least aggressive setting and is less likely to detect labels, poor quality, thick or wrinkled documents as
-Medium: use Medium sensitivity if your application has varying document thickness or labels attached to the document. Depending on the label material, most documents with labels should not be detected as a
-High: the most aggressive setting. This is a good setting to use if all documents are similar in thickness to
•Action — select an option of how you want to the scanner to perform if it detects a
-Beep and continue: if selected, the scanner will beep, display and log the condition but continue to operate.
-End of Job: if selected, the scanner log the condition and stop the feeder and transport (the scanner will be disabled).
•Alarm — select this option if you want the scanner to make a sound when a
106 |