Windows - FastManage Configuration Utilities

3.11 Troubleshooting FastManage

The following table lists problems that may occur with FastManage; it also lists possible solutions.

Problem

Solution

 

 

SNMP community strings are

Change the community strings in the

defaulted to public and private

issnmp.ini Þle

 

 

Unable to start the FastManage

Restart Windows.

application. A message such as

 

ÒUnable to start protocol stackÓ

 

displays

 

 

 

Applications start, but do not display

Restart Windows. Verify Þrmware agent

connected ports or SNMP statistics

is compatible with FastManage

 

 

Can not start applications and the

Reinstall FastManage with IP and IPX

message ÒIP_STACK section

protocols.

issnmp.ini Þle needs IPADDR= setÓ

 

appears

 

 

 

The message ÒUnable to Þnd and

Load IPX drivers before starting

start net driverÓ appears

Windows.

 

 

The message ÒNo Netware

Load VLM.EXE before starting

connections foundÓ when running

Windows.

Discovery or ÒHost not in IPX binderyÓ

 

appears

 

 

 

3.11.1 Error Messages

The following table contains error messages that you may see while using the FastManage Network Manager.

F

A S T M A N A G E

July 1998

3-33

Page 60
Image 60
Kodak 3H0610, Kodak 10/100 Network Interface Card manual Troubleshooting FastManage, Problem Solution, Error Messages