Line Command Mode

9: Line and Tunnel Settings

Line Command Mode

Figure 9-4 Line 1 Command Mode

Setting the Command Mode enables the CLI on the serial line.

To configure Command

Mode on a specific line:

1.Select Line on the menu bar, if you are not already in the Line web page.

2.Select a line number at the top of the page.

3.Select Command Mode. The Command Mode page for the selected line appears.

4. Enter or modify the following settings:

 

Table 9-5Line Command Mode

 

 

Line – Command Mode

Description

Settings

 

Mode

Select the method of enabling Command Mode or choose to disable

 

Command Mode.

 

Always = immediately enables Command Mode for the serial line.

 

Use Serial String = enables Command Mode when the serial string is

 

read on the serial line during boot time.

 

Disabled = turns off Command Mode.

 

 

Wait Time

Enter the wait time for the serial string during boot-up in milliseconds.

 

 

Serial String

Enter the serial string characters. Select a string type.

 

Text = string of bytes that must be read on the Serial Line during boot

 

time to enable Command Mode. It may contain a time element in x

 

milliseconds, in the format {x}, to specify a required delay.

 

Binary = string of characters representing byte values where each

 

hexadecimal byte value starts with \0x and each decimal byte value starts

 

with \.

 

 

Echo Serial String

Select Yes to enable echoing of the serial string at boot-up.

 

 