Lantronix EDS4100 Line and Tunnel Settings, 22 Tunnel Modem Emulation, Click Submit, Description

Models: EDS8PR EDS16PR EDS4100 EDS16PS EDS8PS EDS32PR

1 163
Download 163 pages 27.88 Kb
Page 74
Image 74
Table 9-22Tunnel Modem Emulation

9: Line and Tunnel Settings

Figure 9-21 Tunnel 1 Modem Emulation

4. Enter or modify the following settings:

 

Table 9-22Tunnel Modem Emulation

 

 

Tunnel- Modem

Description

Emulation Settings

 

Echo Pluses
Select Enabled to echo +++ when entering modem Command Mode.

 

 

Echo Commands
Select Enabled to echo the modem commands to the console.

 

 

Verbose Response
Select Enabled to send modem response codes out on the serial line.

 

 

Response Type
Select the type of response code: Text or Numeric.

 

 

Error Unknown

Select whether an ERROR or OK response is sent in reply to unrecognized AT

Commands
commands. Choices are:

 

Enabled = ERROR is returned for unrecognized AT commands.

 

Disabled = OK is returned for unrecognized AT commands. Default is Disabled.

Incoming

Select whether Incoming Connection requests will be disabled, answered

Connection
automatically, or answered manually. Default is Disabled.
Connect String

Enter the connect string. This modem initialization string prepares the modem for

 

communications. It is a customized string sent with the “CONNECT” modem

 

response code.

 

 

Display Remote IP

Selects whether the incoming RING sent on the Serial Line is followed by the IP

 

address of the caller. Default is Disabled.

5.Click Submit.

6.Repeat above steps as desired, according to additional tunnel(s) available on your product.

EDS User Guide