9: Line and Tunnel Settings

 

 

 

 

 

Tunnel - Accept Mode

Description

 

 

Settings (continued)

 

 

 

Flush Serial Data

Select Enabled to flush the serial data buffer on a new connection.

 

 

 

 

 

 

Block Serial Data

Select On to block, or not tunnel, serial data transmitted to the device.

 

 

 

 

 

 

Block Network

Select On to block, or not tunnel, network data transmitted to the device.

 

 

 

 

 

 

Password

Enter a password that clients must send to the device within 30 seconds from

 

 

 

opening a network connection to enable data transmission.

 

 

 

The password can have up to 31 characters and must contain only alphanumeric

 

 

 

characters and punctuation. When set, the password sent to the device must be

 

 

 

terminated with one of the following: (a) 0x0A (LF), (b) 0x00, (c) 0x0D 0x0A (CR

 

 

 

LF), or (d) 0x0D 0x00.

 

 

 

 

 

 

Email on Connect

Select whether the device sends an email when a connection is made. Select

 

 

 

None if you do not want to send an email. Otherwise, select the Email profile to

 

 

 

use for sending.

 

 

 

 

 

 

Email on Disconnect

Select whether the device sends an email when a connection is closed. Select

 

 

 

None if you do not want to send an email. Otherwise, select the Email profile to

 

 

 

use for sending.

 

5.Click Submit.

6.Repeat above steps as desired, according to additional tunnel(s) available on your product.

EDS User Guide

65

Page 65
Image 65