DeviceInitiated Email

Specify what credentials will be used when communicating to the SMTP

 

None

server.

 

Use Device SMTP Credentials

Notes:

 

UserInitiated Email

None is the factory default setting for DeviceInitiated Email and

 

None

UserInitiated Email.

 

Use Device SMTP Credentials

“Device Userid” and “Device password” are used to log in to the

 

Use Session User ID and Password

SMTP server when Use Device SMTP Credentials is selected.

 

Use Session Email address and Password

 

 

Prompt user

 

 

 

 

 

Device Userid

 

 

 

 

 

Device password

 

 

 

 

 

Kerberos 5 Realm

 

 

 

 

 

NTLM Domain

 

 

 

 

Security menu

Miscellaneous Security Settings menu

 

Use

To

 

 

 

 

Login Restrictions

Limit the number and time frames of failed login attempts from the printer control

 

Login Failures

panel before all users are locked out.

 

Failure Time Frame

Notes:

 

Lockout Time

Login Failures specifies the number of failed login attempts before users are

 

Panel Login Timeout

 

locked out. Settings range from 1–10. 3 attempts is the factory default setting.

 

Remote Login Timeout

 

Failure Time Frame specifies the time frame during which failed login attempts

 

 

 

 

can be made before users are locked out. Settings range from 1–60 minutes. 5

 

 

minutes is the factory default setting.

 

 

Lockout Time specifies how long users are locked out after exceeding the login

 

 

failures limit. Settings range from 1–60 minutes. 5 minutes is the factory

 

 

default setting. 1 indicates the scanner does not impose a lockout time.

 

 

Panel Login Timeout specifies how long the scanner remains idle on the home

 

 

screen before automatically logging the user off. Settings range from 1–900

 

 

seconds. 30 seconds is the factory default setting.

 

 

Remote Login Timeout specifies how long a remote interface remains idle

 

 

before automatically logging the user off. Settings range from 1–120 minutes.

 

 

10 minutes is the factory default setting.

 

 

 

 

Minimum PIN Length

Limit the digit length of the PIN.

 

1–16

Note: 4 is the factory default setting.

 

 

 