Chapter 7 Usage of Various Functions

7. 2 Special module

The special module and allocated data registers are as followings.

 

 

 

 

 

Item

 

 

 

Data

 

 

 

A/D

 

 

Analog

RTD input

Expansion

Combination module

Conversion

D/A Conversion module

Register

timer

module

 

 

 

module

 

 

 

 

 

 

 

 

 

 

 

 

G7F-ADHA

G7F-ADHB

G7F-AD2A

G7F-DA2I

G7F-DA2V

G7F-AT2A

G7F-RD2A

D4980

 

CH0

CH0

CH0

CH0

CH0

CH0

CH0

 

A/D value

A/D value

A/D value

D/A value

D/A value

A/T value

Temperature

 

 

D4981

 

CH1

CH1

CH1

CH1

CH1

CH1

CH1

 

A/D value

A/D value

A/D value

D/A value

D/A value

A/T value

temperature

 

#1

D4982

CH0

CH0

CH2

CH2

CH2

CH2

CH2

 

 

D/A value

D/A value

A/D value

D/A value

D/A value

A/T value

temperature

 

 

D4983

 

-

CH1

CH3

CH3

CH3

CH3

CH3

 

D/A value

A/D value

D/A value

D/A value

A/T value

temperature

 

 

 

D4984

 

CH0

CH0

CH0

CH0

CH0

CH0

CH0

 

A/D value

A/D value

A/D value

D/A value

D/A value

A/T value

temperature

 

 

D4985

 

CH1

CH1

CH1

CH1

CH1

CH1

CH1

 

A/D value

A/D value

A/D value

D/A value

D/A value

A/T value

temperature

 

#2

D4986

CH0

CH0

CH2

CH2

CH2

CH2

CH2

 

 

D/A value

D/A value

A/D value

D/A value

D/A value

A/T value

temperature

 

 

D4987

 

-

CH1

CH3

CH3

CH3

CH3

CH3

 

D/A value

A/D value

D/A value

D/A value

A/T value

temperature

 

 

 

D4988

 

CH0

CH0

CH0

CH0

CH0

CH0

CH0

 

A/D value

A/D value

A/D value

D/A value

D/A value

A/T value

temperature

 

 

D4989

 

CH1

CH1

CH1

CH1

CH1

CH1

CH1

 

A/D value

A/D value

A/D value

D/A value

D/A value

A/T value

temperature

 

#3

D4990

CH0

CH0

CH2

CH2

CH2

CH2

CH2

 

 

D/A value

D/A value

A/D value

D/A value

D/A value

A/T value

temperature

 

 

D4991

 

-

CH1

CH3

CH3

CH3

CH3

CH3

 

D/A value

A/D value

D/A value

D/A value

A/T value

temperature

 

 

 

RTD input module store digital conversion value of temperature value to data registers as below

Expansion

 

Temperature

 

 

Digital conversion value

 

Ch 0

Ch 1

Ch 2

Ch 3

Ch 0

Ch 1

Ch 2

Ch 3

 

#1

D4980

D4981

D4982

D4983

D4780

D4781

D4782

D4783

#2

D4984

D4985

D4986

D4987

D4784

D4785

D4786

D4787

#3

D4988

D4989

D4990

D4991

D4788

D4789

D4790

D4791

Remark

1)Offset/gain value can’t be changed, it is fixed.

2)Analog inputting is set the current since this is manufactured.

3)Extend to use max.3 Modules

7-39

Page 123
Image 123
LG Electronics 120S user manual D4980