Chapter 7 Usage of Various Functions

(d) 2-phase multiplication mode (MUL4)

-Up or Down is set automatically by the phase difference between A and B phase.

Up counter

-At the rising edge of A-Phase pulse when B-phase is ‘low’.

-At the falling edge of A-Phase pulse when B-phase is ‘high’.

-At the rising edge of B-Phase pulse when A-phase is ‘high’.

-At the falling edge of B-Phase pulse when A-phase is ‘low’.

Up counter

-At the rising edge of A-Phase pulse when B-phase is ‘high’.

-At the falling edge of A-Phase pulse when B-phase is ‘low’.

-At the rising edge of B-Phase pulse when A-phase is ‘low’.

-At the falling edge of B-Phase pulse when A-phase is ‘high’.

A-phase input pulse

B-phase input pulse

Current value

10

11

12

13

14

15

16

17

18

17

16

15

14

13

(3) Preset setting

(a)Internal Preset

-Set internal preset area and preset value.

-Current value of high speed counter is replaced with preset value at the rising edge of internal preset device.

(b)External Preset

-Set external preset area and preset value.

-External devices are fixed as following

Ch0 : P4, Ch1 : P5, Ch2 : P6, Ch3 : P7

-Current value of high speed counter is replaced with preset value at the rising edge of external preset device. 7-8