Chapter 7 Usage of Various Functions

2) Error code

 

Error

 

 

 

 

Condition

 

 

Operation

 

 

Corrective action

 

 

code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H10

 

Acceleration time of basic parameter is out of range

 

 

Stop

 

 

Set Acceleration time within 0~10,000 range

 

H11

 

Deceleration time of basic parameter is out of range

 

 

Stop

 

 

Set Deceleration time within 0~10,000 range

 

H12

 

Speed limit of basic parameter is out of range

 

 

Stop

 

 

Set speed limit within 5~ 100,000 range.

 

H13

 

Bias speed of basic parameter is out of range

 

 

Stop

 

 

Set bias speed within 5 ~ 100,000 range.

 

H14

 

 

Backlash compensation of basic parameter is out of range

 

 

Stop

 

 

Set backlash compensation within 0~ 1,000 range

 

H15

 

JOG high speed of parameter is out of range

 

 

Stop

 

 

Set JOG high speed within bias speed ~ speed limit

 

H16

 

JOG low speed of parameter is out of range

 

 

Stop

 

 

Set JOG high speed within 5 ~ JOG high speed

 

H17

 

Origin return high speed of parameter is out of range

 

 

Stop

 

 

Set Origin return high speed within bias speed ~ speed limit

 

H18

 

Origin return low speed of parameter is out of range

 

 

Stop

 

 

Set Origin return low speed within bias speed ~ Origin return high speed

 

H19

 

Dwell time of parameter is out of range

 

 

Stop

 

 

Set Dwell time within 0 ~ 10000.

 

H20

 

Operation speed of positioning parameter is out of range

 

 

Stop

 

 

Set Operation speed within bias speed ~ speed limit

 

H21

 

Dwell time of pulse out parameter is out of range

 

 

Stop

 

 

Set Dwell time of pulse out parameter within 0 ~ 10000

 

H30

 

POSIST command can’t be executed during operation

 

 

Operating

 

Check if positioning operation is executing when POSIST signal occur.

 

H31

 

POSIST command can’t be executed when output is prohibited

 

Stop

 

 

Check if output is prohibited when POSIST signal occur. Output can be

 

 

 

 

 

enabled by POSCTR command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H32

 

 

POSIST command

can’t be executed when origin is

not

 

Stop

 

 

Check if origin is not designated when POSIST signal occur.

 

 

 

determined

 

 

 

 

 

 

Origin can be designated by POSORG or POSPRS command.

 

 

 

 

 

 

 

 

 

 

 

 

H33

 

Step No. of POSIST command can’t be over 20

 

 

Stop

 

 

Set step No. within 0~20

 

H34

 

POSDST command can’t be executed during operation

 

 

Operating

 

Check if positioning operation is executing when POSDST signal occur.

 

H35

 

 

POSDST

command

can’t

be executed when output

is

 

Stop

 

 

Check if output is prohibited when POSDST signal occur. Output can be

 

 

 

prohibited

 

 

 

 

 

 

 

enabled by POSCTR command.

 

 

 

 

 

 

 

 

 

 

 

 

 

H36

 

 

POSDST

command

can’t

be executed when origin is

not

 

Stop

 

 

Check if origin is not designated when POSDST signal occur.

 

 

 

determined

 

 

 

 

 

 

Origin can be designated by POSORG or POSPRS command.

 

 

 

 

 

 

 

 

 

 

 

 

H37

 

Operation speed of POSDST command is out of range

 

 

Stop

 

 

Set Operation speed within 5 ~ speed limit

 

H38

 

POSVEL command can’t be executed during operation

 

 

Operating

 

Check if positioning operation is executing when POSVEL signal occur.

 

H39

 

 

POSVEL

command

can’t

be executed when output

is

 

Stop

 

 

Check if output is prohibited when POSVEL signal occur. Output can be

 

 

 

prohibited

 

 

 

 

 

 

 

enabled by POSCTR command.

 

 

 

 

 

 

 

 

 

 

 

 

 

H3A

 

Operation speed of POSVEL command is out of range

 

 

Stop

 

 

Set Operation speed within 5 ~ speed limit

 

H3B

 

 

POSJOG command can’t be executed during operation

 

 

Operating

 

Check if positioning operation is executing when POSJOG signal occur.

 

H3C

 

 

POSJOG

command

can’t

be executed when output

is

 

Stop

 

 

Check if output is prohibited when POSJOG signal occur. Output can be

 

 

 

prohibited

 

 

 

 

 

 

 

enabled by POSCTR command.

 

 

 

 

 

 

 

 

 

 

 

 

 

H3D

 

Direction can’t be changed in JOG operation

 

 

Operating

 

 

Change direction after JOG operation end.

 

H3E

 

 

PWM command can’t be executed during operation

 

 

Operating

 

Check if positioning operation is executing when PWM signal occur.

 

H3F

 

PWM command can’t be executed when output is prohibited

 

 

Stop

 

 

Check if output is prohibited when PWM signal occur. Output can be enabled

 

 

 

 

 

 

by POSCTR command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H40

 

PWM period of PWM command is out of range

 

 

Stop

 

 

Set period within 1 ~ 20,000

 

H41

 

Off duty of PWM command is out of range

 

 

Stop

 

 

Set duty within 0 ~ 100

 

H42

 

POSSOR command is available during operating only

 

 

Stop

 

 

Check if positioning operation is not executing when POSSOR signal occur.

 

H43

 

Speed override value of POSSOR command is out of range

 

 

Operating

 

 

Set override value within 5 ~ speed limit

 

 

 

 

 

 

 

 

 

7-102

 

 

 

 