Chapter 7 Usage of Various Functions

(2) Origin return parameter

(A) Origin return method

For the details, please refer to ‘7) Return to Origin’ in chapter 7.3.2

(B) DOG, origin signal

 

Ch 0

Ch 1

DOG

P0005

P0007

 

 

 

Origin

P0004

P0006

 

 

 

(C)Origin return speed

The speed when returning to the origin by origin return command : high speed and low speed

When setting the origin return speed, it should be “speed limit ≥ origin return high speed ≥ origin return low speed ≥ bias speed”.

Origin return high speed

The speed that acts to the constant speed section via acceleration section by origin return command.

Origin return-high speed setting range : 5 100,000(unit: 1pps)

Origin return-Low speed

The speed that acts to the constant speed section via deceleration section by origin return command.

Origin return-low speed setting range : 5 100,000(unit: 1pps)

Remark

When setting the origin return speed, it is recommended to set the origin return-low speed as low speed as possible. If setting the low speed as “too fast”, it may cause the incorrect origin signal detection.

(D)Dwell Time

This is the time needed to maintain the precise stop accuracy of SERVO motor when using the SERVO motor for positioning.

Practically, Dwell time is the time needed to remove the residual pulse of deviation counter after completion of positioning and especially Dwell time when returning to the origin is called as “origin return dwell time”.

Setting range of Origin return dwell time : 0 10,000(unit: 1 )

7-87