Single Module UPS Installation

1.4Positioning

The cabinet is mounted on four castor-wheels for ease of positioning and for short distance movement. Jacking feet are provided to prevent the UPS from moving once it has been wheeled to its final posi- tion.

For optimal design life, the place chosen must offer:

Easy connection

Enough space to easily work on the UPS

Sufficient air exchange of enough to dispel heat produced by UPS

Protection against atmospheric agents

Protection against excessive humidity and very high heat sources

Protection against dust

Compliance with the current fire prevention requirements

Operating environment temperature between 20°C and 25°C (68 and 77°F). The batteries are at maximum efficiency in this temperature range (see Table 30).

The UPS cabinet is constructed around a steel chassis with removable panels. The top and side panels are secured to the chassis by screws.

Access to the power terminals, auxiliary terminals blocks and power switches is from the front. Oper- ational status and alarm information is provided through the front door operator control panel. Mod- els 30kVA and below house both the power components and an internal battery. Cooling air enters the front of the NX and is exhausted out the rear.

1.4.1System Cabinets

A UPS may comprise a number of cabinets, depending on the design requirements (e.g., UPS cabinet, external battery cabinet, external bypass cabinet). In general, all the Liebert cabinets used in a particu- lar installation are of the same height and designed to be positioned side-by-side to form a matching array.

Refer to 4.0 - Installation Drawings for assistance on positioning the cabinets described below.

1.4.210 to 30kVA UPS

The UPS consist of a single cabinet, which uses typically forty (40) 12V battery blocks, fitted inter- nally and connected in series to provide a nominal battery voltage. The UPS may be shipped without the batteries fitted.

An extended battery option is available. This comprises a separate cabinet containing additional bat- teries that can be connected to the UPS to increase its battery run time.

1.4.3Moving the Cabinets

! WARNING

Ensure that any equipment used to move the UPS cabinet has sufficient lifting capacity.

The UPS is fitted with casters. Take care to prevent the NX from moving when unbolting the unit from its shipping pallet. Ensure that adequate personnel and lifting aids are available when removing the shipping pallet.

Ensure that the UPS weight is within the designated surface weight loading of any handling equip- ment. See Table 32.

UPS and optional cabinets (battery cabinets, top cable entry cabinets, etc.) can be handled by means of a forklift or similar equipment.

The UPS cabinet also can be moved short distances by its casters.

NOTE

Care must be taken when maneuvering units fitted with batteries. Keep such moves to a minimum.