Figure i Model number nomenclature

 

 

 

 

 

NXe

0

 

 

A0

010

 

U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Feature Set for Region

 

 

 

Input &

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A0

- EMEA

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B0

- Aust/NZ

 

 

 

Voltage

 

 

 

 

 

 

Output kVA

 

 

 

 

 

 

 

 

C0

- Japan

 

 

 

 

 

 

 

 

 

 

010

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D0

- China

 

 

 

 

 

 

Revision

 

 

 

 

 

 

 

 

 

E0 - Latin Amer

 

 

015

 

 

 

 

to Base

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

 

F0 - Other

 

 

020

 

 

 

 

 

 

 

 

 

 

 

 

NX Product Line

UPS Single Module

50/60Hz

Voltage

Code

 

 

220/380

F

 

 

230/400

U

 

 

240/415

G

 

 

Liebert NXe UPS module ratings:

10, 15, 20, 30kVA (with internal battery)

Example: NXE0A0010U =

10kVA module for Europe and Middle East, 400V/230V output

Options

Model

 

 

Identification

Note

 

 

 

Battery cabinet

NXE0NBCS

 

 

 

 

Battery Ground Fault detection kit

NXA0UFXBGF

 

 

 

 

Battery temperature probe (for external battery)

NXA0UFXBTS

 

 

 

 

Maintenance bypass cabinet (separate bypass input)

NXE0NMBX

Specify total system kVA

 

 

 

Fan Redundancy kit

NXE0UFXRF

Specify UPS kVA rating

 

 

Seismic Anchor kit

NXA0UFXSAN

 

 

 

 

Dual bus control cable 05-10-15 metres

NXA0UFXD

Specify length in metres

 

 

Parallel control cable kit 05-10-15 metres

NXA0UFXP

 

 

 

 

Relay Card (On Bat, Bat Low, On Byp, Sum, UPS Fail)

RELAYCARD-INT

 

MultiPort4 (4 sets On Bat, bat Low)

MULTIPORT 4

These are Intellislot plug-in cards (3 slots

Web browser/TCPIP/SNMP Card

OCWEB-LB

available).

Jbus/Modbus Card

OC485CARD

 

RAM - Remote Alarm Monitor

NXA0CFXRAM

Requires RELAYCARD-INT

 

 

 

Modem card

NXA0CFXMOD

 

 

 

 

Extended LBS box

NXA0UFXLBS

 

 

 

 

Air Filter

NXA0UFXARF

One filter

 

 

 

 

 

(XXX: 050 or 150) - Specify length in

Dual Bus Extension Kit 50-150 Meters

NXXXXMLBSKIT

meters. Used for extension in length or

dual bus arrangement between Nx and

 

 

 

 

non-Nx sources'

 

 

 

 

BDS 40 or

Specify number of blocks. Consult

Individual Battery Monitoring

Emerson Network Power representatives

BDS 256

 

for complete configuration

 

 

 

 

 

vi

Page 8
Image 8
Liebert NX UPS System user manual Feature Set for Region Input, Output, Aust/NZ, Options Model Identification