Configuring WAN Access
Configuring inbound calls
MAX 6000/3000 Network Configuration Guide 3-65
Unspecified Max HDLC=0
Unspecified Max V110=0
Limiting all calls that do not specify a DNIS number
To specify that the MAX unit accepts twenty calls, of any type, that do not specify a DNIS
number, set the following parameters as shown:
Unspecified Max Calls=20
Unspecified Max Modem=20
Unspecified Max HDLC=20
Unspecified Max V110=20
Limiting V.110 calls to a specific DNIS number
To specify that the MAX unit accepts fifteen simultaneous V.110 calls that specify a DNIS
number of 1212 and allows 100 simultaneous calls to any DNIS number except 1212, set the
following parameters as shown:
DNIS #1 Max Calls=15
DNIS #1 Modem=0
DNIS #1 HDLC=0
DNIS #1 V110=15
Unspecified Max Calls=100
Unspecified Modem Calls=100
Unspecified HDLC Calls=0
Unspecified V110 Calls=0