4-110 MAX 6000/3000 Network Configuration Guide
Configuring Individual WAN Connections
Configuring POTS capability on the MAX 6000 and MAX 3000
Phone Number=
Src Slot=0
Src Port=0
Call Rte Type=Trunk-Voice
Dst Chan Grp=N/A or 0
Dst Trnk Grp=8
Dst Slot=0
Dst Port=0
Dial Plan=0
Rewrt Pattn=
Rewrt Replce=
Use call-setup parameters
To configure call-setup parameters for a PRI line, set the Use Dial Plan parameter in one or
more Call Routes profiles, and define the dial plan (or plans). For example:
System
Sys Config
System
Dial Plan
DPprofile1
Name=DPprofile1
Call-By-Call=1
System
Call Routes
CRprofile1
Name=CRprofile1
Active=Yes
Phone Number=
Src Slot=0
Src Port=0
Call Rte Type=Trunk-Voice
Dst Chan Grp=N/A or 0
Dst Trnk Grp=0
Dst Slot=0
Dst Port=0
Dial Plan=1
Rewrt Pattn=
Rewrt Replce=