Log Messages

Message descriptions

“Descriptor Sync Error from RC, int1=%d”

LOG_FILE:/var/log/gr.console

SOURCE_FILE: rx/tbsi_svc.c

SCOPE:CARD

CONTEXT:RUNNING

SEVERITY: FATAL

DESCRIPTION: This message is logged when the RX-CPU detects that the CPU and the RC are out-of-synch. This is a fatal error. The card is reset and automatically reloaded. int1 is the content of the RC’s interrupt register.

“Descriptor Sync Error from TC, int1=%d”

LOG_FILE:/var/log/gr.console

SOURCE_FILE: tx/tbsi_svc.c

SCOPE:CARD

CONTEXT:RUNNING

SEVERITY: FATAL

DESCRIPTION: This message is logged when the TX-CPU detects that the CPU and the TC are out-of-synch. This is a fatal error, the card is reset and reloaded automatically. int1 is the content of the TC’s interrupt register.

“Discarding msg, unknown msg_type 0x%x”

LOG_FILE:/var/log/gr.console

SOURCE_FILE: rx/tbsi_rx.c

SCOPE:CARD

CONTEXT:RUNNING

SEVERITY: WARNING

DESCRIPTION: This message is logged when the SP Switch Router Adapter card receives a message with unknown message type. This message is an indication of software mismatched between processor nodes and the gateway node (SP Switch Router Adapter card). To correct the problem, upgrade the nodes with the latest released microcode..

“ERR! Duplicated buffer %d”

LOG_FILE:/var/log/gr.console

SOURCE_FILE: rx/tbsi_rx.c

SCOPE:CARD

CONTEXT:RUNNING

SEVERITY:WARNING

DESCRIPTION: This message is logged when the RX CPU has detected a duplicated condition of a buffer. This is an indication that there is an error in the receive logic. The receive logic will attempt to recover from the error. If the problem persists, please contact Customer Support.

B-6

SP Switch Router Adapter Guide - 1.4 Update 2

Page 120
Image 120