Manitowoc Ice QF2200 Section, Electrical System, Component Specifications and Diagnostics, 6-47

Models: QF2200 QF0400 QC0700 QF0800 QF2300

1 150
Download 150 pages 297 b
Page 109
Image 109
Component Specifications and Diagnostics

Section 6

Electrical System

 

 

Component Specifications and Diagnostics

ICE/OFF/CLEAN TOGGLE SWITCH

Function

The switch is used to place the ice machine in ICE, OFF or CLEAN mode of operation.

Specifications

Single-pole, single-throw switch. The switch is connected into a varying low D.C. voltage circuit.

Check Procedure

NOTE: Because of a wide variation in D.C. voltage, it is not recommended that voltage is used to check toggle switch operation.

1.Inspect the toggle switch for correct wiring.

2.Isolate the toggle switch by disconnecting all wires from the switch, or by disconnecting the Molex connector from the control board.

3.Check across the toggle switch terminals using a calibrated ohm meter. Note where the wire numbers are connected to the switch terminals, or refer to the wiring diagram to take proper readings.

Switch Setting

Terminals

Ohm Reading

 

 

 

 

19-20

Closed

 

 

 

ICE

19-23

Open

 

 

 

 

20-23

Open

 

 

 

 

19-20

Open

 

 

 

CLEAN

19-23

Closed

 

 

 

 

20-23

Open

 

 

 

 

19-20

Open

OFF

 

 

19-23

Open

 

 

 

 

20-23

Open

 

 

 

4.Replace the toggle switch if ohm readings do not match all three switch settings.

BIN LEVEL PROBE

Function

The bin level probe shuts off the ice machine after the bin fills with ice.

To start ice making, the bin level probe must be open (Bin Level light off). If the probe is closed (Bin Level light on) when the toggle switch is moved to ICE, the control system waits until the bin level probe opens (Bin Level light off) before starting an ice making sequence. If the bin level probe is disconnected from the circuit board, the ice machine will not start. This prevents overfilling the bin with ice.

FAILURE MODES

Bin Level Probe Open or Disconnected

The ice machine will not start and continuously flashes the Bin Level light. Opening the bin level probe for

15 continuous seconds in the Freeze cycle will initiate an Automatic Shut-Off sequence.

Bin Level Probe Closed or Shorted

The ice machine will not start and the Bin Level light is energized.

Shorting the probe for 30 continuous seconds in the Freeze cycle will initiate an Automatic Shut-Off sequence.

CHECK PROCEDURE

Bin Level Probe Open or Disconnected

The ice machine will not start and continuously flashes the Bin Level light.

1.Move toggle switch from OFF to ICE to OFF to ICE to verify ice machine is not in an 8-minute lockout.

Control Board

Cause

Bin Level Light

 

 

 

 

Ice machine was in an

Off

Automatic Shut-Off mode

 

(8-minute lockout).

 

 

Flashes

Go to step 2.

 

 

Part No. 80-1214-3

Revised 8/2003

6-47

 

 

Page 109
Image 109
Manitowoc Ice QF2200, QF2300 Section, Electrical System, Component Specifications and Diagnostics, 6-47, Check Procedure