Problem

Possible Cause

To Correct

 

 

 

Ice machine does not operate.

No electrical power to the ice machine.

Replace the fuse/reset the breaker/turn on

 

 

main power switch/plug cord into receptacle.

 

Control Board fuse open

 

 

 

 

ICE/OFF/CLEAN toggle switch set improperly.

Move toggle switch to the ICE position.

 

 

 

 

8 minute lockout has not expired.

Bin level light will flash to indicate 8 minute

 

 

lockout has not expired. Refer to Sequence of

 

 

Operation

 

 

 

 

Bin level sensor is disconnected or is

Connect bin level sensor or remove ice

 

contacting the ice.

contacting probe.

 

 

 

 

High Pressure Control is open.

Clean condenser, check fan motor, check high

 

 

pressure control operation. Check for

 

 

refrigerant overcharge or non-condensables in

 

 

system.

 

 

 

Gear Motor runs but

Water reservoir is empty. (Water must contact

Open water service valve or clean float valve

compressor will not start.

the water level probe to start the compressor).

screen. Check water level probe

 

 

 

 

Water level probes out of position

Correct water level probe position.

 

 

 

Remotes Only

No electrical power to condensing unit

Replace the fuse/reset the breaker/turn on the

 

 

main power switch.

 

 

 

Ice machine stops and can be

The SafeGuard feature is stopping the ice

Refer to “SafeGuard Feature” in this section

restarted by moving the toggle

machine.

 

switch to OFF and back to ICE.

 

 

 

 

 

Ice quality is poor.

Poor incoming water quality.

Test the quality of the incoming water and

 

 

check filter.

 

 

 

 

Water filtration is poor.

Replace filter.

 

 

 

 

Incoming water temperature is above 90°F

Correct water temperature. (Verify check/

 

(32.3°C)

mixing valves in other equipment are working

 

 

properly). Connect the ice machine to a cold

 

 

water supply.

 

 

 

 

Water pressure is low.

Water pressure must remain between 20 and

 

 

80 psig.

 

 

 

 

Water softener is working improperly (if

Repair the water softener.

 

applicable).

 

 

 

 

Low ice capacity.

Water float valve screen is dirty.

Remove and clean the filter screen.

 

 

 

 

Incoming water supply is shut-off.

Open the water service valve.

 

 

 

 

Water dump valve is leaking.

Clean the dump valve.

 

 

 

 

Water Pressure is low.

Water pressure must remain between 20 and

 

 

80 psig.

 

 

 

 

Incoming water temperature is above 90°F

Correct water temperature. (verify check/

 

(32.2°C)

mixing valves in other equipment is working

 

 

properly)

 

 

 

 

Water float valve stuck open or leaking.

Remove the float valve and clean it.

 

 

 

Air-Cooled Models Only

Objects stacked around ice machine, blocking

Remove items blocking airflow.

 

airflow to condenser.

 

 

 

 

 

High air temperature around ice machine.

Air temperature must not exceed 110°F

 

 

(43.3°C)

 

 

 

 

Inadequate clearance around the ice machine.

Provide adequate clearance.

 

 

 

 

The condenser is dirty.

Clean the condenser.

 

 

 