Manitowoc Ice QF0400, QF2300, QF0800, QC0700, QF2200 service manual Section, Electrical System, 6-11

Models: QF2200 QF0400 QC0700 QF0800 QF2300

1 150
Download 150 pages 297 b
Page 73
Image 73
6-11

Section 6

Electrical System

 

 

Initial Start-Up or Start-Up After Automatic Shut-Off (cont.)

1B. WATER FILL

After 45 seconds the float valve solenoid is energized.

L1

 

 

 

 

 

 

 

 

 

 

L2 (N)

GROUND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(21)

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

K2

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

HIGH

CONTACTOR

 

 

 

 

 

PRESSURE

 

 

 

 

K1

(90)

CUT-OUT

(95)

COIL

(65)

C4

 

 

 

 

 

 

 

 

 

 

 

POTENTIAL

 

10 AMP

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

GEARMOTOR

 

(25)

FUSE

 

 

 

 

 

 

 

 

 

 

 

(46)

 

 

(21)

 

(43)

RUN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

(22)

 

 

CAPACITOR

 

RELAY K4

 

 

 

 

 

 

 

K3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WATER FLOAT

 

 

 

 

 

 

 

 

 

VALVE COIL

 

 

 

 

 

 

(52)

 

 

 

 

 

 

 

(56)

 

 

 

 

 

 

 

 

 

 

 

 

C4

(22)

 

 

 

 

 

 

 

 

 

 

POTENTIAL

 

 

 

 

 

 

 

 

 

 

 

RELAY

(51)

 

 

 

 

(55)

 

 

 

 

 

 

 

 

 

 

 

 

FAN MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

DUMP VALVE COIL

(AIR-COOLED ONLY)

CONTACTOR

 

 

 

 

 

 

 

 

 

 

FAN CYCLE

 

 

 

 

 

COIL

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

RUN CAPACITOR

 

 

 

 

 

 

 

 

 

 

(41)

 

L1

T1

 

 

 

 

 

 

 

 

 

 

 

 

 

C

COMPRESSOR

 

 

 

 

 

 

 

 

 

C4

 

 

CONTACTOR

 

OVERLOAD

 

 

 

 

 

R

(45)

POTENTIAL

 

 

CONTACTS

 

 

 

S

 

 

(49)

C5

C2

 

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(61)

C4

 

 

 

 

 

 

 

C1

RUN

 

 

POTENTIAL

 

 

 

 

 

 

(31)

CAPACITOR

(62)

RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

START

 

 

SV3124

 

 

 

 

 

 

 

CAPACITOR

 

 

 

 

 

 

 

 

 

 

 

1B. Water Fill

(Until Water Contacts Water Level Probe)

 

 

 

Toggle Switch

 

ICE

 

 

 

Bin Level Probe

 

Open (No Ice Contact)

 

 

 

Control Board Relays

 

 

 

 

 

 

#1

Contactor Coil

 

Open / OFF

 

 

 

 

 

Compressor

 

OFF

 

 

 

 

 

Condenser Fan Motor

 

OFF

 

 

 

 

#2

Dump Valve

 

OFF

 

 

 

 

#3

Gear Motor

 

ON

 

 

 

 

#4

Water Float Valve Solenoid Coil

 

ON

 

 

 

 

Part No. 80-1214-3

Revised 8/2003

6-11

 

 