Section 6 | Electrical System |
|
|
QF2200
Automatic
L1
L2 |
GROUND |
An 8 minute lockout starts when the compressor
8 Minute Lockout
The bin level light will flash until the 8 minute lockout expires. After the 8 minute lockout time can be overridden by moving the ON/OFF/ CLEAN toggle switch for ICE to OFF and back to ICE.
|
| LIQUID LINE |
| |
RELAY |
| (54) | SOLENOID | (53) |
K2 |
|
| ||
| RELAY | CENTRIFUGAL | ||
| K1 | |||
|
| SWITCH |
| |
(25) |
|
|
| |
|
|
|
| |
7 AMP |
| INTERNAL |
|
|
FUSE |
|
|
| |
| (65) | OVERLOAD | START |
|
|
|
| ||
|
|
|
| |
| RELAY |
| RUN |
|
RELAY K4 |
|
|
| |
K3 |
|
|
| |
|
| GEARMOTOR |
| |
(52) | WATER FLOAT |
|
|
|
| VALVE COIL |
|
|
|
|
| (56) |
|
|
(22) |
|
|
|
|
(51) | (55) |
|
| |
|
|
|
| |
| DUMP VALVE |
|
|
|
| COIL |
|
|
|
|
|
|
| SV3048 |
Automatic
Toggle Switch | ICE | |
|
| |
Bin Level Probe | CLOSED ( Ice Contacting probe) | |
|
| |
Control Board Relays |
| |
|
|
|
#1 | Liquid Line Solenoid Valve | OFF |
|
|
|
#2 | Dump Valve | OFF |
|
|
|
#3 | Gear Motor | OFF |
|
|
|
#$ | Water Float Valve Solenoid Coil | OFF |
|
|
|
Part No. | Revised 8/2003 |
|
|
|