Manitowoc Ice QF0400, QF2300 Section, Ice Machine Operation, 3-13, Water Reservoir Cover Removal

Models: QF2200 QF0400 QC0700 QF0800 QF2300

1 150
Download 150 pages 297 b
Page 43
Image 43
QF2300 Shown

Section 3

Ice Machine Operation

 

 

Water Reservoir Cover Removal

QF2300

1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.

2.Remove water level probes.

3.Remove water float valve coil.

4.Depress coil and rotate 1/4 turn counterclockwise.

5.With coil wires attached, lift coil off enclosure tube.

6.Remove top cover from float reservoir.

3, 4, 5

2

6

SV1791

QF2300 Shown

Float Valve Removal

1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.

2.Disconnect water supply line at float valve quick disconnect by depressing stainless steel lever.

3.Remove water float valve coil.

4.Depress coil and rotate 1/4 turn counterclockwise.

5.With coil wires attached, lift coil off enclosure tube.

6.QF0800/QC0700/QF2300 ONLY Rotate quarter turn fasteners counterclockwise.

7.QF0800/QC0700 ONLY Remove cotter key and pin from ice chute.

8.Remove top cover from float reservoir.

9.Lift float valve out of float reservoir.

FLOAT VALVE

SV2015

QC700/QF800 Shown

Part Number 80-1214-3

3-13

Page 43
Image 43
Manitowoc Ice QF0400 Section, Ice Machine Operation, 3-13, Water Reservoir Cover Removal, QF2300 Shown, QC700/QF800 Shown