Section 6 | Electrical System |
|
|
4.Disconnect water level probe from control board. Install jumper from control board “water level” terminal to ground.
5.Move the toggle switch from ICE to OFF to ICE position. Wait 45 seconds, then monitor the Water Level Probe light.
Step 5 Jumper “water level” terminal to ground
Water Level light is: | Compressor | Cause |
|
|
|
|
| Replace water level probe wiring. |
On | Energizes | (Verify defective component – ohm wire from |
|
| connector to connector.) |
|
|
|
Off | Remains | Replace control board. |
|
|
|
DISCONNECT
WATER LEVEL PROBE.
JUMPER FROM
CONTROL BOARD “WATER LEVEL” TO
GROUND
WATER LEVEL
PROBE LIGHT
SV2035
WATER LEVEL PROBE CLOSED OR SHORTED
1.Disconnect the water level probe from the control board.
2.Move the toggle switch to the ICE position, wait 45 seconds and then monitor the Water Level Probe light.
Step 2 Disconnect water level probe from control board “water level” terminal
Water Level light is: | Compressor | Cause |
|
|
|
Off | Remains | Clean water level probe. |
|
|
|
On | Energizes | Replace control board. |
|
|
|
DISCONNECT
WATER LEVEL PROBE.
WATER LEVEL | SV2036 |
PROBE LIGHT |
Part No. | Revised 8/2003 |
|
|
|