5-10

Troubleshooting

Section 5

 

 

QF2200/QF2300

The evaporator and motor / gearbox are separate assemblies. Warranty procedures require replacement of the entire evaporator or motor /gearbox assembly. Separate components are not available, and field rebuilding during the warranty period is not allowed.

1.Disconnect power and water supply to the ice machine and drain all water from the reservoir and evaporator.

2.Remove reservoir retaining pin, water reservoir, ice chute, and drain tubing (refer to Component Removal).

3.Recover refrigerant and disconnect refrigeration tubing from evaporator.

4.Remove foundation-coupling bolts.

5.Lift evaporator out of foundation coupling and remove from ice machine.

6.Remove spline hub and keyway from evaporator (8 mm hex wrench for coupling set screw).

7.Apply anti-seize compound to the shaft and all bolts to ease future disassembly.

8.After reinstallation of evaporator, torque foundation bolts to 195-205 inch lbs.

REMOVE

FOUNDATIONSV3017

BOLTS

5-10

Revised 8/2003

Part No. 80-1214-3

 

 

Page 62
Image 62