Troubleshooting | Section 5 |
|
|
QF2200/QF2300
The evaporator and motor / gearbox are separate assemblies. Warranty procedures require replacement of the entire evaporator or motor /gearbox assembly. Separate components are not available, and field rebuilding during the warranty period is not allowed.
1.Disconnect power and water supply to the ice machine and drain all water from the reservoir and evaporator.
2.Remove reservoir retaining pin, water reservoir, ice chute, and drain tubing (refer to Component Removal).
3.Recover refrigerant and disconnect refrigeration tubing from evaporator.
4.Remove
5.Lift evaporator out of foundation coupling and remove from ice machine.
6.Remove spline hub and keyway from evaporator (8 mm hex wrench for coupling set screw).
7.Apply
8.After reinstallation of evaporator, torque foundation bolts to
REMOVE
FOUNDATIONSV3017
BOLTS
| Revised 8/2003 | Part No. |
|
|