6-33

Section 6

Electrical System

 

 

RFC2385

L1

Automatic Shut-Off

When the refrigerant pressure is low enough to open the low-pressure switch, the contactor coil is de- energized and the compressor and condenser fan motor stop.

GROUND

COMPRESSOR

L2

 

CRANKCASE

 

(94)

HEATER

(95)

 

C1

 

C2

(96)

(85)

(74)

 

 

 

 

CONTACTOR

HIGH PRESSURE

LOW PRESSURE

COIL

CUT-OUT

CUT-OUT

 

CONTACTOR

 

CONTACTOR

CONTACTS

FAN MOTOR

CONTACTS

RUN

CAPACITOR

(50)

 

 

 

(49)

 

RUN

 

COMPRESSOR

 

 

 

(47)

 

CAPACITOR

 

C

S

 

 

 

 

 

 

(46)

 

R

 

 

 

(45)

OVERLOAD

 

 

 

 

(48)

 

 

 

(44)

 

 

 

 

 

 

 

5

2

1

 

(43)

 

RELAY

START

 

 

CAPACITOR

SV2121

3. Automatic Shut-Off (45 Seconds)

High Pressure Control

Low Pressure Control

Contactor Coil

Compressor

Condenser Fan Motor

CLOSED

OPEN

OPEN / OFF

OFF

OFF

Part No. 80-1214-3

Revised 8/2003

6-33

 

 

Page 95
Image 95