6-12

Electrical System

Section 6

 

 

Freeze Cycle

L1

2. FREEZE

The gear motor, compressor, condenser fan motor and water float valve solenoid remain energized as the ice machine makes ice. The water float valve will open and close automatically to maintain the proper water level.

L2 (N)

GROUND

 

 

 

 

 

 

 

 

 

 

 

(21)

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

K2

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

HIGH

CONTACTOR

 

 

 

 

 

PRESSURE

 

 

 

 

K1

(90)

CUT-OUT

(95)

COIL

(65)

C4

 

 

 

 

 

 

 

 

 

 

 

POTENTIAL

 

10 AMP

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

GEARMOTOR

 

(25)

FUSE

 

 

 

 

 

 

 

 

 

 

 

(46)

 

 

(21)

 

(43)

RUN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

(22)

 

 

CAPACITOR

 

RELAY K4

 

 

 

 

 

 

 

K3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WATER FLOAT

 

 

 

 

 

 

 

 

 

VALVE COIL

 

 

 

 

 

 

(52)

 

 

 

 

 

 

 

(56)

 

 

 

 

 

 

 

 

 

 

 

 

C4

(22)

 

 

 

 

 

 

 

 

 

 

POTENTIAL

 

 

 

 

 

 

 

 

 

 

 

RELAY

(51)

 

 

 

 

(55)

 

 

 

 

 

 

 

 

 

 

 

 

FAN MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

DUMP VALVE COIL

(AIR-COOLED ONLY)

CONTACTOR

 

 

 

 

 

 

 

 

 

 

FAN CYCLE

 

 

 

 

 

COIL

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

RUN CAPACITOR

 

 

 

 

 

 

 

 

 

 

(41)

 

L1

T1

 

 

 

 

 

 

 

 

 

 

 

 

 

C

COMPRESSOR

 

 

 

 

 

 

 

 

 

C4

 

 

CONTACTOR

 

OVERLOAD

 

 

 

 

 

R

(45)

POTENTIAL

 

 

CONTACTS

 

 

 

S

 

 

(49)

C5

C2

 

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(61)

C4

 

 

 

 

 

 

 

C1

RUN

 

 

POTENTIAL

 

 

 

 

 

 

(31)

CAPACITOR

(62)

RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

START

 

 

 

 

 

 

 

 

 

 

CAPACITOR

 

SV3125

 

 

 

 

 

 

 

 

 

 

 

2. Freeze (Until Ice Contacts Bin Level Probe for 30 Continuous Seconds)

Toggle Switch

Bin Level Probe

Control Board Relays

#1 Contactor Coil

Compressor

Condenser Fan Motor

#2 Dump Valve

#3 Gear Motor

#4 Water Float Valve Solenoid Coil

ICE

Open (No Ice Contact)

Closed / ON

ON

ON

OFF

ON

ON

6-12

Revised 8/2003

Part No. 80-1214-3

 

 

Page 74
Image 74
Manitowoc Ice QF2200, QF2300, QF0800, QC0700, QF0400 service manual Electrical System, Section, 6-12, Freeze Cycle