Electrical Service

Section 2

Installation Instructions

 

 

Electrical Service

GENERAL

!Warning

All wiring must conform to local, state and national codes.

VOLTAGE

The maximum allowable voltage variation is ±10% of the rated voltage on the ice machine model/serial number plate at start-up (when the electrical load is highest).

!Warning

The ice machine must be grounded in accordance with national and local electrical codes.

FUSE/CIRCUIT BREAKER

A separate fuse/circuit breaker must be provided for each ice machine. Circuit breakers must be H.A.C.R. rated (does not apply in Canada).

QF400 115/60/1 ice machines are factory pre-wired with a power cord and 5-15P plug confirmation. QF400 230/50/1 ice machines are factory pre-wired with a power cord, no plug is supplied. QF2200/QF2300 with Remote Condensing Unit the ice machine head section and remote condensing unit are wired independent of each other. A separate dedicated fuse/circuit breaker must be provided for each section. Circuit breakers must be H.A.C.R. rated (does not apply in Canada).

MINIMUM CIRCUIT AMPACITY

QC700/QF800/QF2200/QF2300 Only

The minimum circuit ampacity is used to help select the wire size of the electrical supply. (Minimum circuit ampacity is not the ice machine’s running amp load.) The wire size (or gauge) is also dependent upon location, materials used, length of run, etc., so it must be determined by a qualified electrician.

Part No. 80-1214-3

Revised 8/2003

2-5

 

 

Page 17
Image 17
Manitowoc Ice QC0700 Section, Installation Instructions, Electrical Service, General, Voltage, Fuse/Circuit Breaker