Section 6 | Electrical System |
|
|
Automatic
An 8 minute lockout starts when the compressor
8 Minute
The bin level light will flash until the 8 minute
After the 8 minute
The 8 minute
L1 |
|
|
|
|
|
|
| L2 (N) |
GROUND |
|
|
|
|
|
|
|
|
(21) |
|
|
|
|
|
|
|
|
|
| RELAY |
|
|
|
|
|
|
|
| K2 |
|
|
|
|
|
|
|
|
| RELAY |
| HIGH | CONTACTOR |
| |
|
|
|
| PRESSURE |
| |||
|
|
| K1 | (90) | (95) | COIL | (65) | |
|
| 10 AMP |
|
|
|
| GEARMOTOR | |
(25) |
| FUSE |
|
|
|
| ||
|
|
|
| (46) |
|
|
| (43) |
|
|
| RELAY |
| (47) |
|
| (48) |
| RELAY K4 |
|
|
|
| |||
| K3 |
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
| WATER FLOAT |
|
|
| GEARMOTOR |
| ||
| VALVE COIL |
|
|
|
| |||
| (56) |
| RUN CAPACITOR |
| ||||
(52) |
|
|
| |||||
|
|
|
|
|
| |||
(22) |
| (55) |
|
|
|
| ||
(51) |
|
|
|
|
| FAN MOTOR | ||
|
|
|
|
| ||||
|
|
|
| (10) | ||||
| DUMP VALVE |
|
|
| ||||
|
|
|
|
|
| |||
|
| COIL |
|
|
|
|
|
|
L1 | T1 | (41) |
|
| (11) |
|
|
|
CONTACTOR |
|
|
|
|
|
| ||
CONTACTS |
|
|
|
|
|
|
| |
|
|
|
| (14) |
|
|
| |
|
|
| RUN |
| START |
|
| |
|
|
|
|
|
| (44) |
|
|
|
|
|
|
|
|
|
| SV3039 |
| Automatic | |
|
| |
Toggle Switch | ICE | |
|
| |
Bin Level Probe | Closed (Ice Contacting Probe) | |
|
| |
Control Board Relays |
| |
|
|
|
#1 | Contactor Coil | Open / OFF |
|
|
|
| Compressor | OFF |
|
|
|
| Condenser Fan Motor | OFF |
|
|
|
#2 | Dump Valve | OFF |
|
|
|
#3 | Gear Motor | OFF |
|
|
|
#4 | Water Float Valve Solenoid Coil | OFF |
|
|
|
Part No. | Revised 8/2003 | |
|
|