Electrical System

 

 

Automatic Shut-Off

An 8 minute lockout starts when the compressor de-energizes. When the ice drops away from the bin level probe the ice machine will begin an initial start-up cycle, provided the “8 minute lock-out” has expired.

8 Minute Lock-out

The bin level light will flash until the 8 minute lock-out expires.

After the 8 minute lock-out expires the bin level light will de-energize.

The 8 minute lock-out time can be overridden by moving the ON/OFF/ ICE toggle switch from ICE to OFF then back to ICE.

L1

 

 

 

 

 

 

 

L2 (N)

GROUND

 

 

 

 

 

 

 

 

(21)

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

 

K2

 

 

 

 

 

 

 

 

 

RELAY

 

HIGH

CONTACTOR

 

 

 

 

 

PRESSURE

 

 

 

 

K1

(90)

CUT-OUT

(95)

COIL

(65)

 

 

10 AMP

 

 

 

 

GEARMOTOR

(25)

 

FUSE

 

 

 

 

 

 

 

 

(46)

 

 

 

(43)

 

 

 

RELAY

 

(47)

 

 

(48)

 

RELAY K4

 

 

 

 

 

K3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WATER FLOAT

 

 

 

GEARMOTOR

 

 

VALVE COIL

 

 

 

 

 

(56)

 

RUN CAPACITOR

 

(52)

 

 

 

 

 

 

 

 

 

(22)

 

(55)

 

 

 

 

(51)

 

 

 

 

 

FAN MOTOR

 

 

 

 

 

(AIR-COOLED ONLY)

 

 

 

 

(10)

 

DUMP VALVE

 

 

 

 

 

 

 

 

 

 

 

COIL

 

 

 

 

 

 

L1

T1

(41)

 

 

(11)

 

 

 

CONTACTOR

 

 

 

 

 

 

CONTACTS

 

 

 

 

 

 

 

 

 

 

 

(14)

 

 

 

 

 

 

RUN

 

START

 

 

 

 

 

 

 

 

(44)

 

 

 

 

 

 

 

 

 

 

SV3039

 

Automatic Shut-Off(Until Ice No Longer Contacts Bin Level Probe)

 

 

Toggle Switch

ICE

 

 

Bin Level Probe

Closed (Ice Contacting Probe)

 

 

Control Board Relays

 

 

 

 

#1

Contactor Coil

Open / OFF

 

 

 

 

Compressor

OFF

 

 

 

 

Condenser Fan Motor

OFF

 

 

 

#2

Dump Valve

OFF

 

 

 

#3

Gear Motor

OFF

 

 

 

#4

Water Float Valve Solenoid Coil

OFF

 

 

 

Part No. 80-1214-3